 MB3505
THRU
MB3510
SINGLE PHASE 35 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
35.0 Amperes
MB-35
FEATURES
* Superior thermal design * 400 amperes surge capability * Mounting: Hole thru for #8 screw * 1/4" universal faston terminal
HOLE FOR NO. 8 SCREW
1.181(30.0) 1.102(28.0)
.673(17.1) .633(16.1)
.452 MAX. (11.5) .480(12.2) .425(10.8)
AC
+
.673(17.1) .633(16.1)
AC
.732(18.6) .692(17.6)
1.181(30.0) 1.102(28.0)
.582(14.8) .543(13.8)
.033X.250 (0.8X6.4)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current .375"(9.5mm) Lead Length at Tc=55 C Peak Forward Surge Current, 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Maximum Forward Voltage Drop per Bridge Element at 17.5AD.C. Maximum DC Reverse Current Ta=25 C at Rated DC Blocking Voltage Operating Temperature Range, TJ Storage Temperature Range, TSTG Ta=100 C
MB3505
MB351
MB352
MB354
MB356
MB358 MB3510 UNITS
50 35 50
100 70 100
200 140 200
400 280 400 35 400 1.1 10 -65 -65 500 +125 +150
600 420 600
800 560 800
1000 700 1000
V V V A A V A A C C
RATING AND CHARACTERISTIC CURVES (MB3505 THRU MB3510)
FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE
60 50 40 30 20 10 0
Single Phase Half Wave 60Hz Resistive Or Inductive Load
FIG.2-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT,(A)
500
AVERAGE FORWARD CURRENT,(A)
400
300
Tj=25 C 8.3ms Single Half Sine Wave JEDEC method
200
100
0
25
50
75
100 125
150
175
CASE TEMPERATURE,( C)
0 1 5 10 50 100
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL FORWARD CHARACTERISTICS 50
INSTANTANEOUS FORWARD CURRENT,(A)
FIG.4-TYPICAL REVERSE CHARACTERISTICS 50
10 3.0 1.0
Tj=25 C Pulse Width 300us 1% Duty Cycle
REVERSE LEAKAGE CURRENT, ( A)
10 3.0 1.0
0.1
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
1.2
1.4
.01
0
20
40
60
80
100 120 140
FORWARD VOLT AGE,(V)
PERCENT OF RATED PEAK REVERSE VOLT AGE, (%)